Choose the result view#
- Open Results → Reverberation.
- Confirm the listening position.
- Read the summary and the decay method it uses.
Choose a decay method#
Choose EDT, T20 or T30 as available. If a method is unavailable, don’t substitute another — the comparison changes.
Read the chart#
- Read the frequency labels and units.
- Click Show selected position to focus on one listening position.
- Compare positions only within the same saved run.
- Gaps and estimate styling are explained in the legend.
Check your result#
You can state the method, frequency range and position behind each value. Acoustic Ray decay and Room Analysis reverberation are different predictions — label them separately.